Unitateak saltzea | : | Set/Sets |
Erabili ingurumena
Giro tenperatura -20 ~ + 55 ℃
Tenperatura erlatiboa% 5 ~% 95Presio atmosferikoa 86-106kpa
Leherketa-froga -20 ~ 70 ℃
Konexioaren egitura eta tamaina:
Hariztutako eraikuntza
Parametroen ezarpena
Main Menu |
Cipher |
Option |
Set value |
Instruction |
Parameter
setting |
10000 |
Language |
Chinese/English |
1. Preset selection 2. Default Chinese |
Mailing address |
0~254 |
1. Enter the device,communication address 2. This option is not available for battery power 3. Select current output product, this setting is invalid 4. Only selected communication products with 485 take effect 5. Default address 001 |
||
Baud rate |
2400、4800、9600、19200 |
1. 1. Preset selection,Baud rate of device communication 2. This option is not available on battery power 3. Select current output product, this setting is invalid 4. Only the communication product with 485 takes effect 5. Default 2400 |
||
Flow unit |
m3/h, m3/m, m3/s, L/h, L/m, L/s, Kg/h, Kg/m, Kg/s |
1. Preset selection 2. The default is m3/h |
||
Range setting |
0~59999 |
1. Input setting 2. Range units change as flow units are modified 3. The default value is 100 |
||
Damping time |
1~16 |
1. Enter the Settings 2. The default value is 04 |
||
Small signal excision |
0~100% |
1. Input setting 2. If the input is greater than 100%, it is equal to 100% 3. Default 0 |
||
Instrument coefficient |
1~9999999 |
1. Input setting 2. Correct the flow value 3. Default 3600 |
||
Set density |
1~59999 |
1. Input setting 2. Modified fluid density 3. Default 1000Kg/ m3 |
||
Output mode |
Pulse output/current output |
1. Preset selection 2. Battery powered does not have this option 3. Select the product with 485 communication function, this setting function is invalid if set to current output, only pulse output can be selected 4. Default current output |
||
Cumulative setting |
0~999999999.999 |
1. Input setting 2. The default value is the actual total value of the system |
||
Current zero correction |
0~5.9999 |
1. Input setting 2. The default value is the factory revision value. Users are prohibited to modify it under special circumstances |
||
Current full degree correction |
0~5.9999 |
1. Input setting 2. The default value is the factory revision value. Users are prohibited to modify it under special circumstances |
Turbina Turbina Flowmeter saltzen den fluxu neurgailua da, hotz edo bero fluxua, maila edo instrumentuak eta bestelako neurgailuak ere baditugu, behar izanez gero, jar zaitez gurekin harremanetan.
Pribatutasun aitorpena: Zure pribatutasuna oso garrantzitsua da guretzat. Gure enpresak agintzen du zure informazio pertsonala ez dezala inolako baimen esplizituak ezagutzera.
Bete informazio gehiago nahi izanez gero, zurekin harremanetan jartzeko
Pribatutasun aitorpena: Zure pribatutasuna oso garrantzitsua da guretzat. Gure enpresak agintzen du zure informazio pertsonala ez dezala inolako baimen esplizituak ezagutzera.